BBL PCR Clean Up Kit Spin Column

Cat# BB-PIK50 (50 preps)


Introduction:

BBL-PCR Clean up Kit is a column based nucleic acid purification kit where the column has silica membrane which is capable of concentrating the DNA fragments from solutions. The purified PCR product is suitable for general applications such as restriction digestion, ligation, PCR amplification and other molecular biology experiments.

This kit can purify DNA fragments of 80 bp to 10Kbp with a recovery rate of more than 75% in less than 15 minutes.

Kit Contents:

Contents

# BB-PCK50

(50 preps)

Binding Buffer

25 ml

Wash Buffer

15 ml

Elution Buffer

15 ml

Spin Column

50 nos

Collection Tubes 2.0 ml

50 nos

Storage:

BBL-PCR Clean up Kit (# BB-PCK50) is stable for 12 months if stored properly in dry place at room temperature (20°C – 25°C) away from direct sunlight.

Note:

  • Add ethanol (96-100%) to Wash buffer before use (see bottle label for volume)
  • All centrifugation steps are carried out at 12000 rpm (~13400xg) in a conventional table top centrifuge at room temperature (15-25°C).
  • Ensure that the elution buffer is dispensed directly onto the membrane for complete elution of bound DNA. The average volume of elution buffer is ~50 µl. Less volume of elution buffer may lead to lower recoveries of DNA.

Protocol

  1. Add 4 volumes of Binding Buffer to 1 volume of the PCR sample and mix. (Removal of mineral oil from the top is not necessary).

For example, add 400 µl of Binding Buffer to 100 µl of PCR sample (not including oil)

  1. Place a spin column in a 2 ml collection tube provided in the kit.
  1. To bind DNA, apply the sample mix, to the spin column. Keep at room temperature for 2 min for binding and centrifuge for 1 min

The maximum volume of the column reservoir is 750 µl. For sample volumes of more than 750 µl, repeat the step 3 again.

  1. Discard the flow through and place the spin column back in the same collection tube.
  1. Add 600 µl of Wash Buffer to the column and centrifuge for 1 min. Discard the flow through and place the spin column into the collection tube.
  1. Repeat the step 5 for one more time.
  1. Discard the flow through and centrifuge the tube for an additional 1 min

Residual ethanol from Wash Buffer will not be completely removed unless the flow through is discarded before this additional centrifugation.

  1. Place the spin column into a fresh, clean 1.5 ml micro centrifuge tube.
  1. To elute DNA, add 50 µl of Elution Buffer to the centre of the membrane. Incubate at room temperature for 3-5 minutes and then centrifuge for 2 min.
  1.  Take 2-5 µl purified DNA for concentration check and electrophoresis and store the rest of the DNA at -20°C for further analysis.